1 change: 1 addition & 0 deletions zhaquirks/quirk_ids.py
Original file line number Diff line number Diff line change
Expand Up @@ -6,6 +6,7 @@
# Tuya
TUYA_PLUG_ONOFF = "tuya.plug_on_off_attributes" # plugs with configurable attributes on the OnOff cluster
TUYA_PLUG_MANUFACTURER = "tuya.plug_manufacturer_attributes" # plugs with configurable attributes on a custom cluster
TUYA_POOL_SENSOR = "tuya.pool_sensor_attributes"

# Xiaomi
XIAOMI_AQARA_VIBRATION_AQ1 = (
Expand Down
269 changes: 269 additions & 0 deletions zhaquirks/tuya/ts0601_pool_sensor.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,269 @@
"""Tuya pool sensor."""

from typing import Any, Dict

from zigpy.profiles import zha
import zigpy.types as t
from zigpy.zcl.clusters.general import Basic, Groups, Ota, Scenes, Time
from zigpy.zcl.clusters.measurement import (
PH,
ChlorineConcentration,
ElectricalConductivity,
SodiumConcentration,
TemperatureMeasurement,
)

from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.quirk_ids import TUYA_POOL_SENSOR
from zhaquirks.tuya import TUYA_QUERY_DATA, TuyaEnchantableCluster, TuyaLocalCluster
from zhaquirks.tuya.mcu import (
DPToAttributeMapping,
EnchantedDevice,
TuyaMCUCluster,
TuyaPowerConfigurationCluster,
)


# XXX: Move this to a shared location later, as the TuyaPowerConfigurationCluster name is used twice:
# once in zhaquirks.tuya and once in zhaquirks.tuya.mcu. Both have a different function.
class TuyaPowerConfigurationSpellCluster(
TuyaEnchantableCluster, TuyaPowerConfigurationCluster
):
"""Doubling, local, and enchantable TuyaPowerConfigurationCluster."""


class TuyaTemperatureMeasurement(TemperatureMeasurement, TuyaLocalCluster):
"""Tuya local TemperatureMeasurement cluster."""


class TuyaPH(PH, TuyaLocalCluster):
"""Tuya local pH cluster."""


class TuyaORP(TuyaLocalCluster):
"""Tuya local Oxido-Reduction Potential cluster."""

cluster_id = 0x042F
name = "ORP Level"
ep_attribute = "redox_potential"

attributes = {
0x0000: ("measured_value", t.Single), # fraction of 1 (one)
0x0001: ("min_measured_value", t.Single),
0x0002: ("max_measured_value", t.Single),
}

server_commands = {}
client_commands = {}


class TuyaTDS(TuyaLocalCluster):
"""Tuya local Total Dissolved Solids cluster."""

cluster_id = 0x0430
name = "TDS Level"
ep_attribute = "total_dissolved_solids"

attributes = {
0x0000: ("measured_value", t.Single), # fraction of 1 (one)
0x0001: ("min_measured_value", t.Single),
0x0002: ("max_measured_value", t.Single),
}

server_commands = {}
client_commands = {}


class TuyaSodiumConcentration(SodiumConcentration, TuyaLocalCluster):
"""Tuya local NaCl cluster."""


class TuyaElectricalConductivity(ElectricalConductivity, TuyaLocalCluster):
"""Tuya local Electrical Conductivity cluster."""


class TuyaChlorineConcentration(ChlorineConcentration, TuyaLocalCluster):
"""Tuya local Chlorine Concentration cluster with a device RH_MULTIPLIER factor."""


class PoolManufCluster(TuyaMCUCluster):
"""Tuya Manufacturer Cluster with Pool data points."""

attributes = TuyaMCUCluster.attributes.copy()
attributes.update(
{
# random attribute IDs
0xEF01: ("ph_min_value", t.uint32_t, True),
0xEF02: ("ph_max_value", t.uint32_t, True),
0xEF03: ("cl_min_value", t.uint32_t, True),
0xEF04: ("cl_max_value", t.uint32_t, True),
0xEF05: ("ec_min_value", t.uint32_t, True),
0xEF06: ("ec_max_value", t.uint32_t, True),
0xEF07: ("orp_min_value", t.uint32_t, True),
0xEF08: ("orp_max_value", t.uint32_t, True),
0xEF09: ("update", t.Single, True),
}
)

def _update_attribute(self, attrid: int, value: Any) -> None:
"""Catch button attribute to emit data_query."""
super()._update_attribute(attrid, value)
if attrid == 0xEF09:
tuya_manuf_cluster = self.endpoint.device.endpoints[1].in_clusters[

Check warning on line 119 in zhaquirks/tuya/ts0601_pool_sensor.py

View check run for this annotation

Codecov / codecov/patch

zhaquirks/tuya/ts0601_pool_sensor.py#L117-L119

Added lines #L117 - L119 were not covered by tests
TuyaMCUCluster.cluster_id
]
tuya_manuf_cluster.command(TUYA_QUERY_DATA)

Check warning on line 122 in zhaquirks/tuya/ts0601_pool_sensor.py

View check run for this annotation

Codecov / codecov/patch

zhaquirks/tuya/ts0601_pool_sensor.py#L122

Added line #L122 was not covered by tests

dp_to_attribute: Dict[int, DPToAttributeMapping] = {
1: DPToAttributeMapping(
TuyaTDS.ep_attribute,
"measured_value",
),
2: DPToAttributeMapping(
TuyaTemperatureMeasurement.ep_attribute,
"measured_value",
converter=lambda x: x * 10,
),
101: DPToAttributeMapping(
TuyaORP.ep_attribute,
"measured_value",
),
102: DPToAttributeMapping(
TuyaChlorineConcentration.ep_attribute,
"measured_value",
),
7: DPToAttributeMapping(
TuyaPowerConfigurationSpellCluster.ep_attribute,
"battery_percentage_remaining",
),
# TODO 103 pH Calibration
# TODO 104 Backlight
# TODO 105 Backlight Value
#
10: DPToAttributeMapping(
TuyaPH.ep_attribute,
"measured_value",
),
11: DPToAttributeMapping(
TuyaElectricalConductivity.ep_attribute,
"measured_value",
),
106: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"ph_max_value",
),
107: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"ph_min_value",
),
108: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"ec_max_value",
),
109: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"ec_min_value",
),
110: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"orp_max_value",
),
111: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"orp_min_value",
),
112: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"cl_max_value",
),
113: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"cl_min_value",
),
# TODO 114: PH Calibration
# TODO 115: EC Calibration
# TODO 116: ORP Calibration
117: DPToAttributeMapping(
TuyaSodiumConcentration.ep_attribute,
"measured_value",
),
}

data_point_handlers = {
1: "_dp_2_attr_update",
2: "_dp_2_attr_update",
101: "_dp_2_attr_update",
102: "_dp_2_attr_update",
7: "_dp_2_attr_update",
10: "_dp_2_attr_update",
11: "_dp_2_attr_update",
106: "_dp_2_attr_update",
107: "_dp_2_attr_update",
108: "_dp_2_attr_update",
109: "_dp_2_attr_update",
110: "_dp_2_attr_update",
111: "_dp_2_attr_update",
112: "_dp_2_attr_update",
113: "_dp_2_attr_update",
117: "_dp_2_attr_update",
}


class TuyaPoolSensor(EnchantedDevice):
"""Tuya Pool sensor."""

quirk_id = TUYA_POOL_SENSOR
tuya_spell_data_query = True

signature = {
# "profile_id": 260,
# "device_type": "0x0051",
# "in_clusters": ["0x0000","0x0004","0x0005","0xef00"],
# "out_clusters": ["0x000a","0x0019"]
MODELS_INFO: [
("_TZE200_v1jqz5cy", "TS0601"),
],
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
PoolManufCluster.cluster_id,
],
OUTPUT_CLUSTERS: [Ota.cluster_id, Time.cluster_id],
}
},
}

replacement = {
ENDPOINTS: {
1: {
DEVICE_TYPE: zha.DeviceType.TEMPERATURE_SENSOR,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
PoolManufCluster,
TuyaTemperatureMeasurement,
TuyaPH,
TuyaORP,
TuyaChlorineConcentration,
TuyaTDS,
TuyaElectricalConductivity,
TuyaSodiumConcentration,
TuyaPowerConfigurationSpellCluster,
],
OUTPUT_CLUSTERS: [Ota.cluster_id, Time.cluster_id],
}
},
}