When binning a tilt series with a transformation matrix associated, it is necessary to correct the scale of the shifts in order to keep the alignment consistent.
The text was updated successfully, but these errors were encountered:
You are right. Let me check why it is failing to me then. The behavior I am experiencing is that when applying ts normalization before reconstruction the final tomogram appears artifacted. This only happens when taking the TS with the associated alignment info (if taking the interpolated tilt series for normalization then the tomogram seems to be correct).
fede-pe
changed the title
Imod tilt-series normalization does not correct transformation matrix
Imod tilt-series normalization is introducing some error in the alignment matrix
Nov 10, 2022
When binning a tilt series with a transformation matrix associated, it is necessary to correct the scale of the shifts in order to keep the alignment consistent.
The text was updated successfully, but these errors were encountered: