Notifications
You must be signed in to change notification settings - Fork 527
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Signed-off-by: ilixiaocui <[email protected]>
- Loading branch information
1 parent
f407c6d
commit 7f89d09
Showing
9 changed files
with
214 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,210 @@ | ||
# Curve块存储性能调优指南 | ||
|
||
## 背景 | ||
|
||
本文档主要描述Curve块存储的参数是如何影响性能的,以及要如何调整,可以使得性能到达最优。 | ||
|
||
## 参考性能 | ||
|
||
测试场景:3台机器*10块/盘 | ||
|
||
盘的型号:Intel® Solid State Drive DC S3510 Series | ||
|
||
测试工具:[curve-fio](https://github.com/opencurve/fio#readme) | ||
|
||
测试版本:v1.2.5 (配置copyset.enable_odsync_when_open_chunkfile=true。 这个选项默认为false,可以优化性能,但是会有iops或者带宽抖动,请根据业务场景进行确定) | ||
|
||
测试卷大小:100GB | ||
|
||
条带化卷参数:stripeUnit=16k stripeCount=64(大io建议创建条带化卷测试) | ||
|
||
### 8k随机写测试数据 | ||
|
||
**客户端个数:** 3 | ||
|
||
**fio配置:** | ||
``` | ||
[global] | ||
bs=8K | ||
iodepth=128 | ||
rw=randwrite | ||
direct=1 | ||
numjobs=1 | ||
size=100G | ||
ioengine=cbd | ||
runtime=999999 | ||
time_based | ||
group_reporting | ||
ramp_time=10s | ||
``` | ||
|
||
**性能数据:** | ||
|iops(k)|avg lat(us)|99th lat(us) | ||
|----|-----|----| | ||
|27.9|4590|27919 | ||
|27.7|4614|27919 | ||
|28.1|4549|27657 | ||
|
||
### 512k顺序写测试数据 | ||
|
||
**客户端个数:** 3 | ||
|
||
**fio配置:** | ||
``` | ||
[global] | ||
bs=512k | ||
iodepth=128 | ||
rw=write | ||
direct=1 | ||
numjobs=1 | ||
size=100G | ||
ioengine=cbd | ||
group_reporting | ||
runtime=90 | ||
ramp_time=10s | ||
``` | ||
|
||
|bandwidth(MB/s)|avg lat(ms)|99th lat(ms) | ||
|----|-----|----| | ||
|338|189|372 | ||
|338|189|485 | ||
|343|186|397 | ||
|
||
|
||
## 影响性能的关键指标 | ||
|
||
性能指标的查看途径有两种: | ||
1. 直接通过服务的ip:port获取 | ||
2. 通过监控查看([块存储监控部署](https://github.com/opencurve/curveadm/wiki/curvebs-monitor-deployment)) | ||
|
||
### 环境配置 | ||
|
||
|
||
环境配置可以参考: [推荐配置设置](https://github.com/opencurve/curve/blob/master/docs/cn/%E6%B5%8B%E8%AF%95%E7%8E%AF%E5%A2%83%E9%85%8D%E7%BD%AE%E4%BF%A1%E6%81%AF.md) | ||
|
||
**需要特别说明的是**,对于使用RAID/SAS卡及Sata SSD的环境,**需要在关闭磁盘缓存后,重启机器,使 RAID/SAS 卡识别磁盘缓存已经关闭。** 如果磁盘缓存打开,对文件的sync操作会发送至磁盘,导致磁盘性能下降。 | ||
|
||
重启后,对SSD盘上的文件系统,进行 fio 测试,验证缓存是否关闭。 | ||
|
||
fio脚本: | ||
|
||
``` | ||
[global] | ||
rw=randwrite | ||
iodepth=1 | ||
ioengine=psync | ||
fdatasync=1 | ||
bsrange=4k-4k | ||
size=4G | ||
numjobs=32 | ||
group_reporting | ||
time_based=1 | ||
thread=1 | ||
runtime=10000 | ||
[disk0] | ||
filename=/data/chunkserver0/data | ||
[disk1] | ||
filename=/data/chunkserver1/data | ||
``` | ||
|
||
> 如果有多个SSD盘,在 fio 脚本的后面加上对应的盘。 | ||
> fio 测试写入的文件,最好提前通过 dd 命令创建或覆盖写一遍,dd if=/dev/zero of=/data/chunkserver0/data bs=1M count=4096 oflag=direct | ||
如果关闭成功,fio 报告的 IOPS 与 iostat -mtx 1 看到的 SSD 盘上的 w/s 是一致的 | ||
|
||
![](../images/0102-diskcache1.jpg) | ||
|
||
如果缓存未关闭或机器未重启,会出现 fio 报告的 IOPS 只有 SSD 盘上 w/s 一半的情况 | ||
|
||
![](../images/0102-diskcache2.jpg) | ||
|
||
### 服务端 | ||
|
||
**1. 复制组的leader在chunkserver上的分布是否均衡** | ||
|
||
在Curve块存储中,所有的读写请求都是发往leader处理的,如果复制组的leader在chunkserver上分布不均衡,会导致chunkserver上接受到请求的压力不同,导致无法完全发挥集群性能。 | ||
|
||
- metric指标查看:```curl leadermdsip:leadermdsport/vars | grep leadernum_range``` | ||
查看chunkserver上leader数量最大和最小的差值, **一般这个值在5以内认为集群是均衡的** | ||
|
||
``` | ||
topology_metric_logical_pool_default_logical_pool_leadernum_range : 1.000 | ||
``` | ||
|
||
- 监控:```MDS DashBord/chunkserver状态 panel``` | ||
|
||
![leadermetric](../images/0102-leadermetric.jpg) | ||
|
||
- leader不均衡时可以通过命令触发快速均衡:```curve_ops_tool rapid-leader-schedule```。这个命令创建的配置变更任务是随着心跳上报的,所以均衡效果在几个心跳周期之后可以看到(默认心跳周期是10s)。 | ||
|
||
**2. 复制组之间的心跳周期** | ||
|
||
在Curve块存储中,复制组的心跳周期通过chunkserver的配置项```copyset.election_timeout_ms=1000```确定,默认是1s。由于复制组的心跳和用户数据的复制都是使用的bthread,当集群压力特别大时,会导致复制组心跳超时,复制组的leader在不断的切换。有三个表现: | ||
- 从监控上可以看到每个chunkserver上的leader不均衡,并且单个chunkserver上的leader总是在变动(参考 **1. 复制组的leader在chunkserver上的分布是否均衡**) | ||
|
||
- 监控项 ```chunkserver Dashbord/线程指标 Panels``` 中bthread的使用率持续飙高。更多信息的获取可以参考[brpc线程数量查看](https://github.com/apache/incubator-brpc/blob/master/docs/cn/server_debugging.md#1%E6%A3%80%E6%9F%A5%E5%B7%A5%E4%BD%9C%E7%BA%BF%E7%A8%8B%E7%9A%84%E6%95%B0%E9%87%8F) | ||
|
||
![bthreadmetric](../images/0102-bthreadcountmetric.jpg) | ||
|
||
- chunkserver的日志中有大量leader选举日志 | ||
|
||
``` | ||
LOG(INFO) << "node " << _group_id << ":" << _server_id | ||
<< " received PreVoteResponse from " << peer_id | ||
<< " term " << response.term() << " granted " << response.granted(); | ||
``` | ||
这会导致client端有很多重试的rpc,加剧集群压力。 | ||
这种情况可以通过增大心跳周期规避leader频繁切换对性能的影响,即chunkserver配置项```copyset.election_timeout_ms=1000```。但这种规避方法不建议在生产环境中使用,复制组的心跳周期变大,会导致异常情况下IO的卡顿时间边长。复制组的心跳不受IO压力影响已经在优化中了,预计Q1会发布版本。 | ||
**3. 查看chunkserver节点上磁盘的压力** | ||
Curve块存储性能测试时,理想的状态是可以把磁盘跑满。如果发现有性能瓶颈,可以先查询一下,磁盘是否被打满。 | ||
- 通过linux命令```iostat```查看磁盘压力情况,一般看观察```util```是否接近100%,cpu 的```idle```是否接近0 | ||
- 通过查看监控项 ```chunkserver Dashbord/Raft关键指标 Panels``` | ||
```storage_append_entries_latency``` : 写盘的延迟(一般ssd的延时在百us~几ms级别;hdd延迟在数十ms级别) | ||
```raft_send_entries_latency```: 一次写盘延迟+一次rpc延迟(一般rpc的延迟在百us~几ms级别) | ||
![latencymetric](../images/0102-latencymetric.jpg) | ||
如果底层磁盘已经压满,理论上就已经达到了集群性能上限。 | ||
### 客户端 | ||
**1. 大IO顺序写场景建议使用条带化卷** | ||
条带化卷的原理可以参考:[条带化设计](https://github.com/opencurve/curve/blob/master/docs/cn/curve-stripe.pdf)。概括来说,条带化是将大IO按照指定的配置,分发到多个复制组上,从而提高性能。 | ||
条带化卷的创建:```curve_ops_tool create -fileName=/test -userName=test -password=123 -fileLength=20 -stripeUnit=32768 -stripeCount=32``` | ||
**2. 直接使用 ```curve fio```测试** | ||
当前Curve块存储支持的几个协议nbd、openstack、iscsi都是要跟Curve[热升级](https://github.com/opencurve/curve/blob/master/docs/cn/nebd.md)模块对接的,在IO链路上会多一次RPC。当前Curve块存储版本已经稳定,如果不考虑热升级,可以去掉热升级模块,提高性能。 | ||
Curve块存储fio的使用方式可以参考:[Fio for Curve README](https://github.com/opencurve/fio#readme) | ||
## 其他指标简析 | ||
详见[Curve块存储监控项说明](https://github.com/opencurve/curve/blob/master/docs/cn/Curve%E7%9B%91%E6%8E%A7%E6%8C%87%E6%A0%87%E8%A7%A3%E6%9E%90.md) | ||
IO过程中全链路关键阶段时延的metric查看(DashBord/Pannel,指标的具体含义请查看[Curve块存储监控项说明](https://github.com/opencurve/curve/blob/master/docs/cn/Curve%E7%9B%91%E6%8E%A7%E6%8C%87%E6%A0%87%E8%A7%A3%E6%9E%90.md)): | ||
``` | ||
client端: | ||
用户接口层指标/client_write_latency | ||
rpc层指标/write_rpc_latency | ||
|
||
chunkserver端: | ||
rpc层读写指标/avg_write_lat | ||
chunkserver层读写指标/avg_write_lat | ||
Raft关键指标/raft_send_entries_latency | ||
Raft关键指标/raft_service_append_entries_latency | ||
Raft关键指标/storage_append_entries_latency | ||
``` |
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.