Add support Sequential mode
Browse files Browse the repository at this point in the history
GOB52 committed Jul 12, 2024
1 parent e6d1db4 commit a7c323c
Showing 3 changed files with 82 additions and 12 deletions.
14 changes: 11 additions & 3 deletions lib/M5Unit-ENV/src/unit/unit_BME688.cpp
Original file line number Diff line number Diff line change
@@ -284,6 +284,12 @@ void UnitBME688::update_bme688() {
return;
}
break;
case Mode::Sequential:
if (!_num_of_data) {
_updated = false;
return;
}
break;
default:
_updated = false;
return;
@@ -604,9 +610,6 @@ bool UnitBME688::measureSingleShot(bme68xData& data) {
auto interval_us = calculateMeasurementInterval(_mode, _tphConf) +
(_heaterConf.heatr_dur * 1000);
auto interval_ms = interval_us / 1000 + ((interval_us % 1000) != 0);
M5_LIB_LOGE(">>>>>> %u/%u/%u %ld", _tphConf.os_temp, _tphConf.os_pres,
_tphConf.os_hum, interval_ms);

m5::utility::delay(interval_ms);

uint32_t retry{10};
@@ -657,6 +660,11 @@ bool UnitBME688::startPeriodicMeasurement(const Mode m) {
}

bool UnitBME688::stopPeriodicMeasurement() {
if (_bsec2_subscription) {
M5_LIB_LOGW("During bsec2 operations");
return false;
}

if (setMode(Mode::Sleep)) {
_periodic = false;
}
6 changes: 3 additions & 3 deletions lib/M5Unit-ENV/src/unit/unit_BME688.hpp
Original file line number Diff line number Diff line change
@@ -523,12 +523,12 @@ class UnitBME688 : public Component {
@param m Mode for measurement
@return True if successful
@pre Calibration,TPH and heater must already be set up
@warning In Forced mode the intervals are constant, but not in other
modes
@warning Measurement intervals are not constant in Parallel mode
*/
bool startPeriodicMeasurement(const bme688::Mode m);
/*!
@brief Stopt periodic measurement
@brief Stop periodic measurement
@return True if successful
*/
bool stopPeriodicMeasurement();
///@}
74 changes: 68 additions & 6 deletions test/embedded/test_bme688/bme688_test.cpp
Original file line number Diff line number Diff line change
@@ -185,7 +185,6 @@ TEST_P(TestBME688, Settings) {
#if defined(UNIT_BME688_USING_BSEC2)
TEST_P(TestBME688, BSEC2) {
SCOPED_TRACE(ustr);
return;

uint8_t cfg[BSEC_MAX_PROPERTY_BLOB_SIZE]{};
uint8_t state[BSEC_MAX_STATE_BLOB_SIZE]{};
@@ -298,7 +297,6 @@ TEST_P(TestBME688, BSEC2) {
}

// TODO: call directly in bsec2

}
#endif

@@ -392,7 +390,8 @@ TEST_P(TestBME688, PeriodicParallel) {
SCOPED_TRACE(ustr);

uint16_t temp_prof[10] = {320, 100, 100, 100, 200, 200, 200, 320, 320, 320};
uint16_t dur_prof[10] = {5, 2, 10, 30, 5, 5, 5, 5, 5, 5};
/* Multiplier to the shared heater duration */
uint16_t mul_prof[10] = {5, 2, 10, 30, 5, 5, 5, 5, 5, 5};

bme68xConf tph{};
tph.os_temp = m5::stl::to_underlying(Oversampling::x2);
@@ -405,7 +404,7 @@ TEST_P(TestBME688, PeriodicParallel) {
bme68xHeatrConf hs{};
hs.enable = true;
memcpy(hs.temp_prof, temp_prof, sizeof(temp_prof));
memcpy(hs.dur_prof, dur_prof, sizeof(dur_prof));
memcpy(hs.dur_prof, mul_prof, sizeof(mul_prof));
hs.shared_heatr_dur = (uint16_t)(140 - (unit->calculateMeasurementInterval(
Mode::Parallel, tph) /
1000));
@@ -421,7 +420,70 @@ TEST_P(TestBME688, PeriodicParallel) {
auto interval = unit->interval();
uint32_t cnt{8};
auto prev = unit->updatedMillis();
auto timeout_at = m5::utility::millis() + (cnt + 1) * 1000;
auto timeout_at = m5::utility::millis() + (interval * 10 * (cnt + 1));
while (cnt && m5::utility::millis() <= timeout_at) {
unit->update();
if (unit->updated()) {
--cnt;
auto um = unit->updatedMillis();
auto duration = um - prev;
prev = um;
// EXPECT_LE(duration, interval);
// M5_LOGW("raw:%u", unit->numberOfRawData());
for (uint8_t i = 0; i < unit->numberOfRawData(); ++i) {
auto d = unit->data(i);
EXPECT_TRUE(d != nullptr);
if (d) {
M5_LOGI("dur:%ld %f/%f/%f/%f", duration, d->temperature,
d->pressure, d->humidity, d->gas_resistance);
EXPECT_TRUE(std::isfinite(d->temperature));
EXPECT_TRUE(std::isfinite(d->pressure));
EXPECT_TRUE(std::isfinite(d->humidity));
EXPECT_TRUE(std::isfinite(d->gas_resistance));
}
}
}
m5::utility::delay(1);
}
EXPECT_EQ(cnt, 0U);

EXPECT_TRUE(unit->stopPeriodicMeasurement());
EXPECT_FALSE(unit->inPeriodic());
EXPECT_EQ(unit->mode(), Mode::Sleep);
}

TEST_P(TestBME688, PeriodiSequential) {
SCOPED_TRACE(ustr);

uint16_t temp_prof[10] = {200, 240, 280, 320, 360, 360, 320, 280, 240, 200};
/* Heating duration in milliseconds */
uint16_t dur_prof[10] = {100, 100, 100, 100, 100, 100, 100, 100, 100, 100};

bme68xConf tph{};
tph.os_temp = m5::stl::to_underlying(Oversampling::x2);
tph.os_pres = m5::stl::to_underlying(Oversampling::x1);
tph.os_hum = m5::stl::to_underlying(Oversampling::x16);
tph.filter = m5::stl::to_underlying(Filter::None);
tph.odr = m5::stl::to_underlying(ODR::None);
EXPECT_TRUE(unit->setTPHSetting(tph));

bme68xHeatrConf hs{};
hs.enable = true;
memcpy(hs.temp_prof, temp_prof, sizeof(temp_prof));
memcpy(hs.dur_prof, dur_prof, sizeof(dur_prof));
hs.profile_len = 10;
EXPECT_TRUE(unit->setHeaterSetting(Mode::Sequential, hs));

//
EXPECT_FALSE(unit->inPeriodic());
EXPECT_TRUE(unit->startPeriodicMeasurement(Mode::Sequential));
EXPECT_TRUE(unit->inPeriodic());
EXPECT_EQ(unit->mode(), Mode::Sequential);

auto interval = unit->interval();
uint32_t cnt{8};
auto prev = unit->updatedMillis();
auto timeout_at = m5::utility::millis() + (interval * (cnt + 1));
while (cnt && m5::utility::millis() <= timeout_at) {
unit->update();
if (unit->updated()) {
@@ -455,5 +517,5 @@ TEST_P(TestBME688, PeriodicParallel) {

TEST_P(TestBME688, SelfTest) {
SCOPED_TRACE(ustr);
// EXPECT_TRUE(unit->selfTest());
EXPECT_TRUE(unit->selfTest());
}