This ZenPack provides additional monitoring options for HP Servers with HP System Insight Manager Agent installed.
You must first have, or install, Zenoss 2.5.2 or later. This ZenPack was tested against Zenoss 2.5.2, Zenoss 3.2 and Zenoss 4.2. You can download the free Core version of Zenoss from http://community.zenoss.org/community/download.
You must first install:
On monitored system, HP System Insight Manager Agents must be installed and properly configured.
Download the HP ProLiant Monitor. Copy this file to your Zenoss server and run the following commands as the zenoss user.
zenpack --install ZenPacks.community.HPMon-2.3.0.egg zenoss restart
If you wish to further develop and possibly contribute back to the HPMon ZenPack you should clone the git repository, then install the ZenPack in developer mode using the following commands.
git clone git://github.com/epuzanov/ZenPacks.community.HPMon.git zenpack --link --install ZenPacks.community.HPMon zenoss restart
Go to the specific device (yes, it needs to already be added).
- From the > Menu select More -> Collector Plugins
- Remove the zenoss.snmp.Cpu
- Click "Add Fields"
- Drag and drop all of the "community.snmp.HP*" entries in the right list over into the left list. Note that community.snmp.HPLogicalDiskMap, community.snmp.HPHardDiskMap and community.snmp.HPExpansionCardMap plugins must be at the END of lists.
- CLICK SAVE (don't forget this step)
- From the > Menu select Manage -> Model Device
- Once it is completed modeling check out the hardware tab for the device, you should see CPUs, Harddrives, Fans, etc. If you don't you may have problems with snmp, so check those settings the usual way.
Installing the ZenPack will add the following items to your Zenoss system.
- zHPExpansionCardMapIgnorePci - ignore PCI cards other than RAID and iLO controllers
- community.snmp.HPCPUMap - CPU modeler plugin
- community.snmp.HPDaCntlrMap - modeler plugin for HP Smart Array controllers
- community.snmp.HPDaLogDrvMap - modeler plugin for Logical Disks on HP Smart Array controllers
- community.snmp.HPDaPhyDrvMap - modeler plugin for Physical Disks on HP Smart Array controllers
- community.snmp.HPDeviceMap - device modeler plugin, tried to identify Model, Vendor and Serial Number
- community.snmp.HPExpansionCardMap - PCI cards modeler plugin, tried to identify all PCI cards, RAID and iLO controllers, put it to the end of *Collector Plugins* list
- community.snmp.HPFanMap - Fan modeler plugin
- community.snmp.HPFcTapeCntlrMap - modeler plugin for FC Tape controllers
- community.snmp.HPFcaCntlrMap - modeler plugin for HP StorageWorks Modular Smart Array controllers
- community.snmp.HPFcaLogDrvMap - modeler plugin for Logical Disks on HP StorageWorks Modular Smart Array controllers
- community.snmp.HPFcaPhyDrvMap - modeler plugin for Physical Disks on HP StorageWorks Modular Smart Array controllers
- community.snmp.HPHardDiskMap - Hard Disks modeler plugin returned to zenmodeler information collected by other Physical Disk modeler plugins, so put it in Collector Plugins list after all Physical Disk modeler plugins.
- community.snmp.HPIdeAtaDiskMap - modeler plugin for IDE/ATA Physical Disks
- community.snmp.HPIdeControllerMap - modeler plugin for IDE/ATA controllers
- community.snmp.HPIdeLogicalDriveMap - modeler plugin for Logical Disks on IDE/ATA controllers
- community.snmp.HPLogicalDiskMap - Logical Disks modeler plugin returned to zenmodeler information collected by other Logical Disk modeler plugins, so put it in Collector Plugins list after all Logical Disk modeler plugins.
- community.snmp.HPMemoryModuleMap - Physical Memory modeler plugin, tried to identify memory modules
- community.snmp.HPNicMap - Network Cards modeler plugin
- community.snmp.HPPowerSupplyMap - Power Supply modeler plugin
- community.snmp.HPSasHbaMap - modeler plugin for SAS controllers
- community.snmp.HPSasLogDrvMap - modeler plugin for Logical Disks on SAS controllers
- community.snmp.HPSasPhyDrvMap - modeler plugin for Physical Disks on SAS controllers
- community.snmp.HPScsiCntlrMap - modeler plugin for SCSI controllers
- community.snmp.HPScsiLogDrvMap - modeler plugin for Logical Disks on SCSI controllers
- community.snmp.HPScsiPhyDrvMap - modeler plugin for Physical Disks on SCSI controllers
- community.snmp.HPSm2CntlrMap - modeler plugin for iLO Management controllers
- community.snmp.HPSsChassisMap - External Chassis modeler plugin
- community.snmp.HPTemperatureSensorMap - Temperature Sensor modeler plugin
- Devices/Server/rrdTemplates/HPFan
- Devices/Server/rrdTemplates/HPPowerSupply
- Devices/Server/rrdTemplates/HPTemperatureSensor
- Devices/Server/rrdTemplates/cpqDaCntlr
- Devices/Server/rrdTemplates/cpqDaCntlrPerf
- Devices/Server/rrdTemplates/cpqDaLogDrv
- Devices/Server/rrdTemplates/cpqDaLogDrvPerf
- Devices/Server/rrdTemplates/cpqDaPhyDrv
- Devices/Server/rrdTemplates/cpqFcaCntlr
- Devices/Server/rrdTemplates/cpqFcaHostCntlr
- Devices/Server/rrdTemplates/cpqFcaLogDrv
- Devices/Server/rrdTemplates/cpqFcaPhyDrv
- Devices/Server/rrdTemplates/cpqHeResMem2Module
- Devices/Server/rrdTemplates/cpqIdeAtaDisk
- Devices/Server/rrdTemplates/cpqIdeController
- Devices/Server/rrdTemplates/cpqIdeLogicalDrive
- Devices/Server/rrdTemplates/cpqNicIfPhysAdapter
- Devices/Server/rrdTemplates/cpqSasHba
- Devices/Server/rrdTemplates/cpqSasLogDrv
- Devices/Server/rrdTemplates/cpqSasPhyDrv
- Devices/Server/rrdTemplates/cpqScsiCntlr
- Devices/Server/rrdTemplates/cpqScsiLogDrv
- Devices/Server/rrdTemplates/cpqScsiPhyDrv
- Devices/Server/rrdTemplates/cpqSiMemModule
- Devices/Server/rrdTemplates/cpqSm2Cntlr
- Devices/Server/rrdTemplates/cpqSsChassis
- Reports/Device Reports/HP ProLiant Reports/Hard Disks
- Reports/Device Reports/HP ProLiant Reports/Storage Controllers
- Reports/Device Reports/HP ProLiant Reports/iLO Boards
- CPQFCA-MIB
- CPQHLTH-MIB
- CPQIDA-MIB
- CPQIDE-MIB
- CPQNIC-MIB
- CPQSCSI-MIB
- CPQSM2-MIB