14 changes: 7 additions & 7 deletions workflow/energy_rating_index.rb
Original file line number Diff line number Diff line change
Expand Up @@ -503,16 +503,16 @@ def get_system_eec(system, type, is_dfhp_primary = nil)
end
elsif type == 'Hot Water'
if not system.energy_factor.nil?
ef_uef = system.energy_factor
ef = system.energy_factor
elsif not system.uniform_energy_factor.nil?
ef_uef = system.uniform_energy_factor
ef = Waterheater.calc_ef_from_uef(system)
end
if ef_uef.nil?
if ef.nil?
# Get assumed EF for combi system

eta_c = system.related_hvac_system.heating_efficiency_afue
if system.water_heater_type == HPXML::WaterHeaterTypeCombiTankless
ef_uef = eta_c
ef = eta_c
elsif system.water_heater_type == HPXML::WaterHeaterTypeCombiStorage
# Calculates the energy factor based on UA of the tank and conversion efficiency (eta_c)
# Source: Burch and Erickson 2004 - http://www.nrel.gov/docs/gen/fy04/36035.pdf
Expand All @@ -530,13 +530,13 @@ def get_system_eec(system, type, is_dfhp_primary = nil)
t_env = 67.5 # F
q_load = draw_mass * cp * (t - t_in) # Btu/day

ef_uef = q_load / ((ua * (t - t_env) * 24.0 + q_load) / eta_c)
ef = q_load / ((ua * (t - t_env) * 24.0 + q_load) / eta_c)
end
end
if not system.performance_adjustment.nil?
ef_uef *= system.performance_adjustment
ef *= system.performance_adjustment
end
return numerator['EF'] / ef_uef
return numerator['EF'] / ef
elsif type == 'Mech Vent Preheating'
return numerator['COP'] / system.preheating_efficiency_cop
elsif type == 'Mech Vent Precooling'
Expand Down