Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathipmi_cmd_ref.txt
177 lines (177 loc) · 9.77 KB
/
ipmi_cmd_ref.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
IPMICFG Version 1.34.2 (Build 230224)
Copyright(c) 2023 Super Micro Computer, Inc.
Usage: IPMICFG params (Example: IPMICFG -m 192.168.1.123)
-help Display a list of commands
-m Shows IPv4 address and MAC.
-m <ip> Sets IPv4 address (format: ###.###.###.###).
-a <mac> Sets MAC (format: ##:##:##:##:##:##).
-k Shows Subnet Mask.
-k <mask> Sets Subnet Mask (format: ###.###.###.###).
-dhcp Gets the DHCP status.
-dhcp on Enables the DHCP.
-dhcp off Disables the DHCP.
-g Shows a Gateway IP.
-g <gateway> Sets a Gateway IP (format: ###.###.###.###).
-garp on Enables the Gratuitous ARP.
-garp off Disables the Gratuitous ARP.
-r Performs a BMC cold reset.
Detects if a BMC reset was successfully performed
on the IPMI device, use -d after -r.
-fd <option> Resets to the factory defaults without preserving
configurations.
option: 1 | Preserves User configurations
option: 2 | Restores to factory default and
default password
option: 3 | Sets user defaults to ADMIN/ADMIN
-fdl Resets IPMI to the factory default. (Clean LAN).
-fde Resets IPMI to the factory default. (Clean FRU &
LAN).
-d Detects if a BMC reset was successfully performed
on the IPMI device.
Note that this option can be only used after -r,
-fd, -fdl or -fde
-ver Gets firmware revision.
-vlan Gets VLAN status.
-vlan on [VLAN tag] Enables the VLAN and sets the VLAN tag.
If VLAN tag is not given, it uses the previously
saved value.
-vlan off Disables the VLAN.
-selftest Checks and reports the basic health status of the
BMC.
-raw Sends a RAW IPMI request and prints a response.
Format: NetFn/LUN Cmd [Data1 ... DataN]
-fru info Shows information of the FRU inventory area.
-fru list Shows all FRU values.
-fru cthelp Shows chassis type code.
-fru help Shows help of FRU Write.
-fru <field> Shows FRU field value.
-fru <field> <value> Writes FRU.
-fru backup <file> Backs up FRU to a file <Binary format>.
-fru restore <file> Restores FRU from a file <Binary format>.
-fru tbackup <file> Backs up FRU to a file <Text format>.
-fru trestore <file> Restores FRU from a file <Text format>.
-fru ver <v1> <v2> Gets/Sets the FRU version. (<v1> and <v2> are
BCD-format)
-sel info Shows SEL information.
-sel list Shows SEL records.
-sel del Deletes all SEL records.
-sel raw Shows SEL raw data.
-sdr [full] Shows SDR records and readings.
-sdr del <sdr id> Deletes the SDR record.
-sdr ver <v1> <v2> Gets/Sets the SDR version. (<v1> and <v2> are
BCD-format)
-nm nmsdr Displays NM SDR.
-nm seltime Gets SEL time.
-nm deviceid Gets the ID of the ME device.
-nm reset Reboots ME.
-nm reset2default Forces ME to reset to default settings.
-nm updatemode Forces ME to enter the update mode.
-nm selftest Gets self-test results.
-nm listimagesinfo Lists ME information of images.
-nm oemgetpower OEM Power command for ME.
-nm oemgettemp OEM Temp. command for ME.
-nm pstate Gets the maximum allowed CPU P-State.
-nm tstate Gets the maximum allowed CPU T-State.
-nm cpumemtemp Gets CPU/memory temperature.
-nm hostcpudata Gets the host CPU data.
-fan Gets the fan mode.
-fan <mode> Sets the fan mode.
-pminfo [full] Displays PMBus health information of power supply.
-psfruinfo Displays FRU health information of power supply.
-psbbpinfo Displays status of the backup battery.
-autodischarge <module> Sets auto discharge by days.
<day>
-discharge <module> Manually discharges a battery.
-user list Lists user privileges.
-user help Shows a user privilege code.
-user add <user id> <name> Adds a user.
<password> <privilege>
-user del <user id> Deletes users.
-user level <user id> Updates user privileges.
<privilege>
-user setpwd <user id> Updates a user password.
<password>
-conf download <file> Downloads IPMI configuration to a binary file.
-conf upload <file> Uploads IPMI configuration from a binary file.
<option> option: -p | Bypass warning message
-conf tdownload <file> Downloads IPMI configuration to a text file.
-conf tupload <file> Uploads IPMI configuration from a text file.
<option> option: -p | Bypass warning message
-clrint Clears chassis intrusion.
-reset <index> Resets system and forces to boot from the selected
device.
-soft <index> Initiates a soft-shutdown for OS and forces system
to boot from the selected device.
-ipv6 mode Shows the IPv6 mode.
-ipv6 mode <mode> Sets the IPv6 mode.
-ipv6 autoconfig Shows IPv6 auto configuration.
-ipv6 autoconfig on Enables IPv6 auto configuration.
-ipv6 autoconfig off Disables IPv6 auto configuration.
-ipv6 list Lists IPv6 static and dynamic addresses.
-ipv6 duid Shows IPv6 DUID.
-ipv6 dns [ip] Gets/Sets IPv6 DNS server.
-ipv6 add <id> <ip> Adds IPv6 static address.
<prefix>
-ipv6 remove <id> Removes IPv6 static address.
-ipv6 route Displays IPv6 static route.
-ipv6 route on Enables IPv6 static route.
-ipv6 route off Disables IPv6 static route.
-ipv6 route list Lists IPv6 static router information.
-ipv6 route <id> <prefix Sets IPv6 static router information.
value> <prefix length>
<ip>
-ipv6 route clear <id> Clears IPv6 static router information.
-nvme list Displays the existing NVME SSD list.
-nvme info Displays NVME SSD information.
-nvme rescan Rescans all devices by in-band.
-nvme insert <aoc> <group> Inserts SSD by out-of-band.
<slot>
-nvme locate <HDD name> Locates SSD. (in-band)
-nvme locate <aoc> <group> Locates SSD. (out-of-band)
<slot>
-nvme stoplocate <HDD Stops locateing SSD. (in-band)
name>
-nvme stoplocate <aoc> Stops locateing SSD. (out-of-band)
<group> <slot>
-nvme remove <HDD name> Removes NVME device. (in-band)
[option1] [option2] option1: 0 | Do eject after remove (Default)
option1: 1 | Do not eject after remove
option2:-p | Bypass warning message
-nvme remove <aoc> <group> Removes NVME device. (out-of-band)
<slot> [option] option: -p | Bypass warning message
-nvme smartdata [HDD name] NVME S.M.A.R.T data.
-tas info Gets TAS information.
-tas pause Pauses a TAS service.
-tas resume Resumes a TAS service.
-tas refresh Triggers TAS to recollect data.
-tas clear Clears collected TAS data in BMC.
-tas period <sec> Sets the time length of a TAS update <limit 1 to 60
sec>.
-tas exec <cmd> Executes a user's specified command.
-tp info Gets MCU information.
-tp info <type> Gets information of MCU type. (type: 1 - 3)
-tp nodeid Gets a node ID.
-tp systemname [value] Gets/Sets a system name.
-tp systempn [value] Gets/Sets a system P/N.
-tp systemsn [value] Gets/Sets a system S/N.
-tp chassispn [value] Gets/Sets a chassis P/N.
-tp chassissn [value] Gets/Sets a chassis S/N.
-tp backplanepn [value] Gets/Sets a backplane P/N.
-tp backplanesn [value] Gets/Sets a backplane S/N.
-tp nodepn [value] Gets/Sets node P/N.
-tp nodesn [value] Gets/Sets node S/N.
-summary Displays FW and BIOS information.
-hostname [value] Gets/Sets a host name.
-dcmi cap Lists information of DCMI capabilities.
-dcmi power Gets the DCMI power readings.
-dcmi ctl [value] Gets/Sets the DCMI management controller ID string.
-mel list Shows BMC maintenance event log.
-mel download <file> Downloads a BMC maintenance event log to a file.
-mel clear Clears a BMC maintenance event log.
-addrptl [option] Gets/Sets IP address protocol.
option: 1 | IPv4
option: 2 | IPv6
option: 3 | Dual
-lockdown Checks the system's lockdown mode.
-lani [option] Gets/Sets LAN interface.
-linkstatus Shows network link status.