Incorrect hostname or port configuration will lead to the initial connection failing with an MQ code of 2538 (MQRC_HOST_NOT_AVAILABLE):
.....2021-04-21 14:02:20.315236: .2021-04-21 14:02:20.315444: BIP1990I: Integration server 'ace-server' starting initialization; version '11.0.0.12' (64-bit)
.................................node.js process.on('exit') event emitted with exitCode of 0
main checker destroyed before initialisation completed, latest stage was MQ default CCSID, pid 1, tid 1, attempted stage was 40 and 39 stages completed
2021-04-21 14:02:25.416076: BIP2116E: IBM App Connect Enterprise internal error: diagnostic information 'Fatal Error; exception thrown before initialisation completed', 'MQ default CCSID', '1', '1', '40', '39'.
2021-04-21 14:02:25.416176: BIP2203E: An integration server has encountered a problem whilst starting.
2021-04-21 14:02:25.416224: BIP2677E: Failed to make a client connection to queue manager 'MQoC' using hostname 'mqoc-419f.qm.eu-gb.mq.appdomainWRONGWRONG.cloud' on port '31175': MQCC=2; MQRC=2538.
2021-04-21 14:02:25.416298: BIP1992I: Integration server 'ace-server' stopped.
In this case, the credentials will not have been used, and may also be invalid, but the server never had a chance to find out.
Incorrect user/password information will lead to the initial connection failing with an MQ code of 2035 (MQRC_NOT_AUTHORIZED):
.....2021-04-21 13:59:23.306262: .2021-04-21 13:59:23.306478: BIP1990I: Integration server 'ace-server' starting initialization; version '11.0.0.12' (64-bit)
.................................node.js process.on('exit') event emitted with exitCode of 0
main checker destroyed before initialisation completed, latest stage was MQ default CCSID, pid 1, tid 1, attempted stage was 40 and 39 stages completed
2021-04-21 13:59:37.404816: BIP2116E: IBM App Connect Enterprise internal error: diagnostic information 'Fatal Error; exception thrown before initialisation completed', 'MQ default CCSID', '1', '1', '40', '39'.
2021-04-21 13:59:37.404912: BIP2203E: An integration server has encountered a problem whilst starting.
2021-04-21 13:59:37.404952: BIP2677E: Failed to make a client connection to queue manager 'MQoC' using hostname 'mqoc-419f.qm.eu-gb.mq.appdomain.cloud' on port '31175': MQCC=2; MQRC=2035.
2021-04-21 13:59:37.405016: BIP1992I: Integration server 'ace-server' stopped.
Incorrect queue manager information will lead to the initial connection failing with an MQ code of 2058 (MQRC_Q_MGR_NAME_ERROR):
.....2021-04-21 13:59:23.306262: .2021-04-21 13:59:23.306478: BIP1990I: Integration server 'ace-server' starting initialization; version '11.0.0.12' (64-bit)
.................................node.js process.on('exit') event emitted with exitCode of 0
main checker destroyed before initialisation completed, latest stage was MQ default CCSID, pid 1, tid 1, attempted stage was 40 and 39 stages completed
2021-04-26 13:20:01.189568: BIP2116E: IBM App Connect Enterprise internal error: diagnostic information 'Fatal Error; exception thrown before initialisation completed', 'MQ default CCSID', '1', '1', '40', '39'.
2021-04-26 13:20:01.189646: BIP2203E: An integration server has encountered a problem whilst starting.
2021-04-26 13:20:01.189683: BIP2677E: Failed to make a client connection to queue manager 'wrongQM' using hostname 'mqoc-419f.qm.eu-gb.mq.appdomain.cloud' on port '31175': MQCC=2; MQRC=2058.
2021-04-26 13:20:01.189737: BIP1992I: Integration server 'ace-server' stopped.
If the mqsisetdbparms alias referenced by the MQEndpoint policy does not exist (as opposed to containing incorrect user/pw information), the server will attempt to start and then fail with a "broken connection" error as follows:
.....2021-04-26 13:31:02.043490: .2021-04-26 13:31:02.043680: BIP1990I: Integration server 'ace-server' starting initialization; version '11.0.0.12' (64-bit)
...................................2021-04-26 13:31:04.052074: BIP2124E: The integration server has detected a condition on thread number '94' with name 'MQQM Monitor Thread', which requires it to shutdown and restart.
2021-04-26 13:31:04.052146: BIP2674E: A broken connection to IBM MQ queue manager has been reported with IBM MQ reason code '?'.
......2021-04-26 13:31:04.097591: BIP2155I: About to 'Initialize' the deployed resource 'AccessMQ' of type 'Application'.
2021-04-26 13:31:04.222005: BIP2155I: About to 'Start' the deployed resource 'AccessMQ' of type 'Application'.
An http endpoint was registered on port '7800', path '/getFlow'.
2021-04-26 13:31:04.243863: BIP3132I: The HTTP Listener has started listening on port '7800' for 'http' connections.
2021-04-26 13:31:04.243941: BIP1996I: Listening on HTTP URL '/getFlow'.
Started native listener for HTTP input node on port 7800 for URL /getFlow
2021-04-26 13:31:04.244135: BIP2269I: Deployed resource 'GetFlow' (uuid='GetFlow',type='MessageFlow') started successfully.
An http endpoint was registered on port '7800', path '/putFlow'.
2021-04-26 13:31:04.244530: BIP3132I: The HTTP Listener has started listening on port '7800' for 'http' connections.
2021-04-26 13:31:04.244584: BIP1996I: Listening on HTTP URL '/putFlow'.
Started native listener for HTTP input node on port 7800 for URL /putFlow
2021-04-26 13:31:04.244743: BIP2269I: Deployed resource 'PutFlow' (uuid='PutFlow',type='MessageFlow') started successfully.
..2021-04-26 13:31:04.690575: BIP2866I: IBM App Connect Enterprise administration security is inactive.
2021-04-26 13:31:04.699800: BIP3132I: The HTTP Listener has started listening on port '7600' for 'RestAdmin http' connections.
.
2021-04-26 13:31:04.701828: BIP1991I: Integration server has finished initialization.
.2021-04-26 13:31:04.702737: BIP9344E: The integration server is shutting down due to an unhandled exception.
2021-04-26 13:31:04.702822: BIP2674E: A broken connection to IBM MQ queue manager has been reported with IBM MQ reason code '?'.
.2021-04-26 13:31:04.702947: .2021-04-26 13:31:04.705546 Watchdog timer start; will exit after 60000ms if shutdown hangs
....
2021-04-26 13:31:08.062141: BIP2155I: About to 'Stop' the deployed resource 'AccessMQ' of type 'Application'.
2021-04-26 13:31:10.196496: BIP2271I: Deployed resource 'GetFlow' (uuid='GetFlow',type='MessageFlow') successfully stopped.
2021-04-26 13:31:10.196702: BIP2271I: Deployed resource 'PutFlow' (uuid='PutFlow',type='MessageFlow') successfully stopped.
2021-04-26 13:31:12.059597: BIP2155I: About to 'TearDown' the deployed resource 'AccessMQ' of type 'Application'.
2021-04-26 13:31:12.083854: BIP3133I: The HTTP Listener has stopped listening on port '7800' for 'http' connections.
node.js process.on('exit') event emitted with exitCode of 0
2021-04-26 13:31:13.109183: BIP1992I: Integration server 'ace-server' stopped.