You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Describe the bug
The scanservjs Docker image 2.27.0 is running without issues. Newer versions like 3.0.3 crash during scanner detection.
I've deleted the docker config and did a clean redeploy of the image to no avail.
To Reproduce Settings > Clears stored scanner devices and forces a reload results in Found no devices while the container log reads:
[2024-03-09T14:44:54.922Z] INFO (Http): { method: 'GET', path: '/api/v1/preview' }
[2024-03-09T14:44:54.923Z] INFO (Process): { execute: '/usr/bin/scanimage -L' }
[2024-03-09T14:44:58.376Z] INFO (Process): { execute: '/usr/bin/scanimage -d genesys:libusb:002:002 -A' }
[2024-03-09T14:44:59.282Z] ERROR (Application): Ignoring genesys:libusb:002:002. Error: Error: Command failed: /usr/bin/scanimage -d genesys:libusb:002:002 -A
Output format is not set, using pnm as a default.
Segmentation fault (core dumped)
However, my scanner is correctly recognized in a container shell:
# scanimage -L
device `genesys:libusb:002:002' is a Canon LiDE 210 flatbed scanner
# scanimage -A
Output format is not set, using pnm as a default.
All options specific to device `genesys:libusb:002:002':
Scan Mode:
--mode Color|Gray [Gray]
Selects the scan mode (e.g., lineart, monochrome, or color).
--source Flatbed [Flatbed]
Selects the scan source (such as a document-feeder).
--preview[=(yes|no)] [no]
Request a preview-quality scan.
--depth 16|8 [8]
Number of bits per sample, typical values are 1 for "line-art" and 8
for multibit scans.
--resolution 4800|2400|1200|600|300|150|100|75dpi [75]
Sets the resolution of the scanned image.
Geometry:
-l 0..216.7mm [0]
Top-left x position of scan area.
-t 0..297.5mm [0]
Top-left y position of scan area.
-x 0..216.7mm [216.7]
Width of scan-area.
-y 0..297.5mm [297.5]
Height of scan-area.
Enhancement:
--custom-gamma[=(yes|no)] [no] [advanced]
Determines whether a builtin or a custom gamma-table should be used.
--gamma-table 0..65535,... [inactive]
Gamma-correction table. In color mode this option equally affects the
red, green, and blue channels simultaneously (i.e., it is an intensity
gamma table).
--red-gamma-table 0..65535,... [inactive]
Gamma-correction table for the red band.
--green-gamma-table 0..65535,... [inactive]
Gamma-correction table for the green band.
--blue-gamma-table 0..65535,... [inactive]
Gamma-correction table for the blue band.
--brightness -100..100 (in steps of 1) [0]
Controls the brightness of the acquired image.
--contrast -100..100 (in steps of 1) [0]
Controls the contrast of the acquired image.
Extras:
--lamp-off-time 0..60 [15]
The lamp will be turned off after the given time (in minutes). A value
of 0 means, that the lamp won't be turned off.
--lamp-off-scan[=(yes|no)] [no]
The lamp will be turned off during scan.
--color-filter Red|Green|Blue [Green]
When using gray or lineart this option selects the used color.
--calibration-file <string> [inactive]
Specify the calibration file to use
--expiration-time -1..30000 (in steps of 1) [60]
Time (in minutes) before a cached calibration expires. A value of 0
means cache is not used. A negative value means cache never expires.
Sensors:
--scan[=(yes|no)] [no] [hardware]
Scan button
--file[=(yes|no)] [no] [hardware]
File button
--email[=(yes|no)] [no] [hardware]
Email button
--copy[=(yes|no)] [no] [hardware]
Copy button
--extra[=(yes|no)] [no] [hardware]
Extra button
Buttons:
--clear-calibration [advanced]
Clear calibration cache
--force-calibration [advanced]
Force calibration ignoring all and any calibration caches
--ignore-internal-offsets [advanced]
Acquires the image including the internal calibration areas of the
scanner
Expected behavior
The UI should recognize my scanner as before.
Server (please complete the following information):
OS: Debian 12
Node version: v18.13.0
Docker version: 25.0.4 build 1a576c5
Logs
see above
The text was updated successfully, but these errors were encountered:
Describe the bug
The scanservjs Docker image 2.27.0 is running without issues. Newer versions like 3.0.3 crash during scanner detection.
I've deleted the docker config and did a clean redeploy of the image to no avail.
To Reproduce
Settings
>Clears stored scanner devices and forces a reload
results inFound no devices
while the container log reads:However, my scanner is correctly recognized in a container shell:
Expected behavior
The UI should recognize my scanner as before.
Server (please complete the following information):
Logs
The text was updated successfully, but these errors were encountered: