Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathdbus-deye-sun-g3-pvinverter.py
executable file
·364 lines (300 loc) · 14.1 KB
/
dbus-deye-sun-g3-pvinverter.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
#!/usr/bin/env python
# import normal packages
import platform
import logging
import sys
import os
import sys
if sys.version_info.major == 2:
import gobject
else:
from gi.repository import GLib as gobject
import sys
import time
import configparser # for config/ini file
from functools import reduce
from pysolarmanv5 import PySolarmanV5
from datetime import datetime
# our own packages from victron
sys.path.insert(1, os.path.join(os.path.dirname(__file__),
'/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
from vedbus import VeDbusService
class DbusDeyeSunG3Service:
def __init__(self, servicename, paths, productname='Deye Sun G3', connection='SolarmanV5 Modbus RTU'):
config = self._getConfig()
deviceinstance = int(config['DEFAULT']['Deviceinstance'])
customname = config['DEFAULT']['CustomName']
self._dbusservice = VeDbusService(
"{}.tcp_{:02d}".format(servicename, deviceinstance))
self._paths = paths
logging.debug("%s /DeviceInstance = %d" %
(servicename, deviceinstance))
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path(
'/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
# self._dbusservice.add_path('/ProductId', 16) # value used in ac_sensor_bridge.cpp of dbus-cgwacs
# id assigned by Victron Support from SDM630v2.py
self._dbusservice.add_path('/ProductId', 0xFFFF)
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/CustomName', customname)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/Latency', None)
self._dbusservice.add_path(
'/FirmwareVersion', self._getDeyeFWVersion())
self._dbusservice.add_path(
'/HardwareVersion', self._getDeyeHWVersion())
self._dbusservice.add_path(
'/Position', int(config['DEFAULT']['Position']))
self._dbusservice.add_path('/Serial', self._getDeyeSerial())
self._dbusservice.add_path('/UpdateIndex', 0)
# Dummy path so VRM detects us as a PV-inverter.
self._dbusservice.add_path('/StatusCode', 0)
# add path values to dbus
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue)
# last update
self._lastUpdate = 0
# add _update function 'timer'
# pause x ms before the next request
updateInterval = int(config['DEFAULT']['UpdateInterval'])
gobject.timeout_add(updateInterval*1000, self._update)
# add _signOfLife 'timer' to get feedback in log every 5minutes
gobject.timeout_add(self._getSignOfLifeInterval()
* 60*1000, self._signOfLife)
def _getDeyeSerial(self):
config = self._getConfig()
serial = config['DEFAULT']['Serial']
return serial
def _getDeyeFWVersion(self):
return self._getFirmwareVersion(None)
# TODO read firmware version over Modbus
# deye_data = self._getDeyeData()
# fwVersion = deye_data['_firmwareVersion']
# return fwVersion
def _getDeyeHWVersion(self):
return 1.0
# TODO read hardware version over Modbus
def _getConfig(self):
config = configparser.ConfigParser()
config.read("%s/config.ini" %
(os.path.dirname(os.path.realpath(__file__))))
return config
def _getSignOfLifeInterval(self):
config = self._getConfig()
value = config['DEFAULT']['SignOfLifeLog']
if not value:
value = 0
return int(value)
def _getDeyeData(self):
config = self._getConfig()
address = config['DEFAULT']['Address']
serial = int(config['DEFAULT']['Serial'])
port = int(config['DEFAULT']['Port'])
modbus = PySolarmanV5(
address=address, serial=serial, port=port, mb_slave_id=1, verbose=False, auto_reconnect=True
)
try:
self._checkResetDailyProduction(modbus)
acEnergyForward = self._getDailyProduction(modbus)
acPower = self._getTotalACOutputPower(modbus)
acCurrent = self._getGridCurrent(modbus)
acVoltage = self._getAcVoltage(modbus)
firmwareVersion = self._getFirmwareVersion(modbus)
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
modbus.disconnect()
return {
"acEnergyForward": acEnergyForward,
"acPower": acPower,
"acCurrent": acCurrent,
"acVoltage": acVoltage,
"_firmwareVersion": firmwareVersion,
}
def _checkResetDailyProduction(self, modbus):
oldValues = modbus.read_holding_registers(register_addr=0x0016, quantity=3)
newValues = self._calcSystemTime()
logging.debug('inverters system time: %s' %oldValues)
logging.debug('new system time: %s' %newValues)
if oldValues[0] != newValues[0] or oldValues[1]/256 != newValues[1]/256:
logging.info('updating inverters system time')
modbus.write_multiple_holding_registers(register_addr=0x0016, values=newValues)
until = time.time() + 5 * 60
while time.time() <= until:
try:
dailyProduction = self._getDailyProduction(modbus)
if dailyProduction <= 0:
logging.info("successful reset of daily production")
return
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
time.sleep(5)
logging.info("timeout on reset of daily production")
def _calcSystemTime(self):
now = datetime.now()
ym = 256 * (now.year % 100) + now.month
dh = 256 * now.day + now.hour
ms = 256 * now.minute + now.second
return [ym, dh, ms]
def _getDailyProduction(self, modbus):
# - name: "Daily Production"
# class: "energy"
# state_class: "total"
# uom: "kWh"
# scale: 0.1
# rule: 1
# registers: [0x003C]
# icon: 'mdi:solar-power'
return modbus.read_holding_register_formatted(register_addr=0x003C, quantity=1, scale=0.1)
def _getAcVoltage(self, modbus):
# - name: "AC Voltage"
# class: "voltage"
# state_class: "measurement"
# uom: "V"
# scale: 0.1
# rule: 1
# registers: [0x0049]
# icon: 'mdi:transmission-tower'
return modbus.read_holding_register_formatted(register_addr=0x0049, quantity=1, scale=0.1)
def _getGridCurrent(self, modbus):
# - name: "Grid Current"
# class: "current"
# state_class: "measurement"
# uom: "A"
# scale: 0.1
# rule: 2
# registers: [0x004C]
# icon: 'mdi:home-lightning-bolt'
return modbus.read_holding_register_formatted(register_addr=0x004C, quantity=1, scale=0.1)
def _getTotalACOutputPower(self, modbus):
# - name: "Total AC Output Power (Active)"
# class: "power"
# state_class: "measurement"
# uom: "W"
# scale: 0.1
# rule: 3
# registers: [0x0056, 0x0057]
# icon: 'mdi:home-lightning-bolt'
values = modbus.read_holding_registers(
register_addr=0x0056, quantity=2)
byteValues = list(map(lambda v: v.to_bytes(2, 'big'), values))
byteValues.reverse()
bytes = reduce(lambda a, b: a + b, byteValues)
intValue = int.from_bytes(bytes, 'big')
value = float(intValue) * 0.1
return value
def _getFirmwareVersion(self, modbus):
# TODO get fw from modbus
config = self._getConfig()
firmwareVersion = config['DEFAULT']['FirmwareVersion']
return firmwareVersion
def _signOfLife(self):
logging.info("--- Start: sign of life ---")
logging.info("Last _update() call: %s" % (self._lastUpdate))
logging.info("Last '/Ac/Power': %s" % (self._dbusservice['/Ac/Power']))
logging.info("--- End: sign of life ---")
return True
def _update(self):
try:
# get data from deye
deye_data = self._getDeyeData()
config = self._getConfig()
str(config['DEFAULT']['Phase'])
pvinverter_phase = str(config['DEFAULT']['Phase'])
# send data to DBus
for phase in ['L1', 'L2', 'L3']:
pre = '/Ac/' + phase
if phase == pvinverter_phase:
self._dbusservice[pre + '/Voltage'] = deye_data['acVoltage']
self._dbusservice[pre + '/Current'] = deye_data['acCurrent']
self._dbusservice[pre + '/Power'] = deye_data['acPower']
self._dbusservice[pre + '/Energy/Forward'] = deye_data['acEnergyForward']
else:
self._dbusservice[pre + '/Voltage'] = 0
self._dbusservice[pre + '/Current'] = 0
self._dbusservice[pre + '/Power'] = 0
self._dbusservice[pre + '/Energy/Forward'] = 0
self._dbusservice['/Ac/Voltage'] = self._dbusservice['/Ac/' + pvinverter_phase + '/Voltage']
self._dbusservice['/Ac/Current'] = self._dbusservice['/Ac/' + pvinverter_phase + '/Current']
self._dbusservice['/Ac/Power'] = self._dbusservice['/Ac/' + pvinverter_phase + '/Power']
self._dbusservice['/Ac/Energy/Forward'] = self._dbusservice['/Ac/' + pvinverter_phase + '/Energy/Forward']
self._dbusservice['/Connected'] = 1
# logging
logging.debug("House Consumption (/Ac/Power): %s" %(self._dbusservice['/Ac/Power']))
logging.debug("House Forward (/Ac/Energy/Forward): %s" %(self._dbusservice['/Ac/Energy/Forward']))
logging.debug("---")
# update lastupdate vars
self._lastUpdate = time.time()
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
try:
if self._lastUpdate < (time.time() - 5 * 60):
self._dbusservice['/Connected'] = 0
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
try:
# increment UpdateIndex - to show that new data is available
index = self._dbusservice['/UpdateIndex'] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice['/UpdateIndex'] = index
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
# return true, otherwise add_timeout will be removed from GObject - see docs http://library.isr.ist.utl.pt/docs/pygtk2reference/gobject-functions.html#function-gobject--timeout-add
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
def main():
# configure logging
logging.basicConfig(format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=logging.INFO,
handlers=[
logging.FileHandler(
"%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
logging.StreamHandler()
])
try:
logging.info("Start")
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
# formatting
def _kwh(p, v): return (str(round(v, 2)) + 'kWh')
def _a(p, v): return (str(round(v, 1)) + 'A')
def _w(p, v): return (str(round(v, 1)) + 'W')
def _v(p, v): return (str(round(v, 1)) + 'V')
# start our main-service
pvac_output = DbusDeyeSunG3Service(
servicename='com.victronenergy.pvinverter',
paths={
# energy produced by pv inverter
'/Ac/Energy/Forward': {'initial': None, 'textformat': _kwh},
'/Ac/Power': {'initial': 0, 'textformat': _w},
'/Ac/Current': {'initial': 0, 'textformat': _a},
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L1/Current': {'initial': 0, 'textformat': _a},
'/Ac/L2/Current': {'initial': 0, 'textformat': _a},
'/Ac/L3/Current': {'initial': 0, 'textformat': _a},
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
'/Ac/L1/Energy/Forward': {'initial': None, 'textformat': _kwh},
'/Ac/L2/Energy/Forward': {'initial': None, 'textformat': _kwh},
'/Ac/L3/Energy/Forward': {'initial': None, 'textformat': _kwh},
})
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
mainloop = gobject.MainLoop()
mainloop.run()
except Exception as e:
logging.critical('Error at %s', 'main', exc_info=e)
if __name__ == "__main__":
main()