Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

OracleBulkCopy and NUMBER with Scale negative #437

Open
FJGR65 opened this issue Jan 18, 2025 · 1 comment
Open

OracleBulkCopy and NUMBER with Scale negative #437

FJGR65 opened this issue Jan 18, 2025 · 1 comment
Labels

Comments

@FJGR65
Copy link

FJGR65 commented Jan 18, 2025

(ODP NET 23.6.1 with .NET Framework 4.8) There is a bug in OracleBulkCopy.WriteToServer when the destination column is of type NUMBER with negative scale. For example:
"Round 100" NUMBER(5, -2)

In these cases, the following exception occurs:

`

{
"$id": "1",
"$type": "Oracle.ManagedDataAccess.Types.OracleTypeException, Oracle.ManagedDataAccess",
"Message": "ORA-13412: invalid scale parameter: 254
https://docs.oracle.com/error-help/db/ora-13412/",
"Number": 0.
"Source": "Oracle Data Provider for .NET, Managed Driver",
"Data": {
"$type": "System.Collections.ListDictionaryInternal, mscorlib"
},
"InnerException": null,
"StackTrace": " at Oracle.ManagedDataAccess.Client.OracleBulkCopy.WriteDataSourceToServer(IBulkCopyDataSource dataSource)
at ExcelToDatabaseWpf.Configuraciones.ConfiguracionHojaExcel.d__89.MoveNext()",
"HelpLink": null,
"HResult": -2146233087
}
`

As is the case with the Oracle ODBC driver, the parameter scale that is created internally is assigned the value 254 (not defined or something like that).

In ODBC the problem arises when you want to insert a NULL. The solution for this problem is to create an OdbcDataAdapter and set the RowUpdating property:

`

OdbcDataAdapter.RowUpdating += this.RowUpdating

Where:

private void RowUpdating(object sender, OdbcRowUpdatingEventArgs e)
{
foreach (OdbcParameter p in e.Command.Parameters)
if (p.Scale == 254 && (p.Value == DBNull.Value || p.Value == null))
p.Scale = 0;
}
`

However, for OracleBulkCopy this solution is not feasible.

@alexkeh
Copy link
Member

alexkeh commented Jan 18, 2025

@FJGR65 Thanks for reporting! I've been able to reproduce your error and created a bug (37494127) to track this issue. The dev team will review this and evaluate how to fix it.

@alexkeh alexkeh added the bug label Jan 18, 2025