Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathDownscaleOilFiredGeneratorsToPlantLevel.m
113 lines (92 loc) · 5.37 KB
/
DownscaleOilFiredGeneratorsToPlantLevel.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
%Michael Craig, 28 May 2015
%This script downscales oil-fired generators to the plant level.
%Lots of oil-fired generators in IPM; for MISO, there are over 1,100
%oil-fired generators, 932 of which are less than 5 MW in size. (526 are
%between 1 and 2 MW, and 218 are less than 1 MW.) To shrink the model size,
%I downscale oil-fired generators to the plant level, of which there are
%351. Heat rates of oil-fired generators do not significantly differ within
%a plant; for most oil-fired plants, generator heat rates are identical, or
%vary by ~1000 or less Btu/kWh. Additionally, unit commitment parameters
%for oil-fired generators don't vary by size (i.e., assume a linear
%relationship between parameters and plant size), and external values of fuel prices and
%emissions rates are used for oil-fired generators, so there is no worry
%about having to average these (although they should be nearly the same for
%generators within a plant anyways). For these reasons, aggregating
%oil-fired generators to the plant level should not affect model accuracy.
%Note that for oil-fired generators w/ a NOx CT (50 have a NOx CT; no other
%CTs are installed on any oil-fired generators), I don't downscale them.
%Procedure:
%1) Identify oil-fired generators
%2) Get unique ORIS IDs
%3) For each unique ORIS ID, get unique generators
%4) Preserve first generator and delete rest - that way, don't have to add
%a whole new row and copy over location and other information
%5) To combine generators: add capacities, average heat rates, average VOM,
%('VOMPerMWhCalculated' col), average FOM ('FOMCost' col).
%6) Delete extra generators
%7) Delete Unit ID of retained generator so don't get confused later, since
%it's no longer that particular unit.
function [futurepowerfleetforplexos] = DownscaleOilFiredGeneratorsToPlantLevel(futurepowerfleetforplexos)
%% GET DATA COLUMNS OF INTEREST IN parseddataworetiredwadjustmentsiso
[parseddataorisidcol,parseddataunitidcol,parseddatafueltypecol,...
parseddataheatratecol, parseddatacapacitycol,parseddataplanttypecol,...
parseddataretrofitcol,parseddataregioncol,parseddatastatecol,parseddatafossilunitcol]=...
GetColumnNumbersFromCPPParsedFile(futurepowerfleetforplexos);
%Also need VOM & FOM columns
vomcol=find(strcmp(futurepowerfleetforplexos(1,:),'VOMPerMWhCalculated'));
fomcol=find(strcmp(futurepowerfleetforplexos(1,:),'FOMCost'));
noxcontrolcol=find(strcmp(futurepowerfleetforplexos(1,:),'NOxControl'));
%% GET ROWS OF OIL-FIRED GENERATORS
rowsofoilgenerators=find(strcmp(futurepowerfleetforplexos(:,parseddatafueltypecol),'Oil'));
%% GET UNIQUE ORIS IDS OF OIL-FIRED GENERATORS
%Isolate ORIS IDs
oilorisids=futurepowerfleetforplexos(rowsofoilgenerators,parseddataorisidcol);
%Get unique ORIS IDs
uniqueoilorisids=unique(oilorisids);
%% DOWNSCALE GENERATORS
%Aggregate generators to plant level, excluding those with a NOx CT
%installed.
%Loop over unique ORIS IDs
rowstodelete=[];
for i=1:size(uniqueoilorisids,1)
%Get current ORIS ID
currorisid=uniqueoilorisids{i};
%Find rows with same ORIS ID
oilrowswithcurrorisid=rowsofoilgenerators(find(strcmp(futurepowerfleetforplexos(rowsofoilgenerators,parseddataorisidcol),currorisid)),:);
%Get CTs of those oil-fired generators - if has a CT, want to drop row
oilcts=futurepowerfleetforplexos(oilrowswithcurrorisid,noxcontrolcol);
%Check which cells are empty (no CT), and for those cells, keep row
nooilcts=cellfun(@isempty,oilcts);
oilrowswithcurrorisid=oilrowswithcurrorisid(nooilcts);
%Check if more than 1 generator; if not, then don't need to do anything
%and move to next loop
if size(oilrowswithcurrorisid,1)>1 %more than 1 generator
%Get row # of first generator
rowoffirstgenerator=oilrowswithcurrorisid(1);
%Sum capacities of all generators at current plant
gencapacities=cell2mat(futurepowerfleetforplexos(oilrowswithcurrorisid,parseddatacapacitycol));
totalplantcapacity=sum(gencapacities);
%Get capacity weights for averages
capacityweights=gencapacities/totalplantcapacity;
%Get avg HR
genheatrates=cell2mat(futurepowerfleetforplexos(oilrowswithcurrorisid,parseddataheatratecol));
avgheatrate=sum(capacityweights.*genheatrates);
%Get capacity-weighted average FOM
genfoms=cell2mat(futurepowerfleetforplexos(oilrowswithcurrorisid,fomcol));
avgfom=sum(capacityweights.*genfoms);
%Get capacity-weighted average VOM
genvoms=cell2mat(futurepowerfleetforplexos(oilrowswithcurrorisid,vomcol));
avgvom=sum(capacityweights.*genvoms);
%Replace capacity, HR, VOM and FOM of first generator
futurepowerfleetforplexos{rowoffirstgenerator,parseddatacapacitycol}=totalplantcapacity;
futurepowerfleetforplexos{rowoffirstgenerator,parseddataheatratecol}=avgheatrate;
futurepowerfleetforplexos{rowoffirstgenerator,vomcol}=avgvom;
futurepowerfleetforplexos{rowoffirstgenerator,fomcol}=avgfom;
%Delete unit ID of first generator
futurepowerfleetforplexos{rowoffirstgenerator,parseddataunitidcol}='';
%Save rows to delete later
rowstodelete=vertcat(rowstodelete,oilrowswithcurrorisid(2:end)); %don't include first row - that's first generator!
end
end
%Delete rows
futurepowerfleetforplexos(rowstodelete,:)=[];