-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathstation_traitement.sql
63 lines (59 loc) · 2.7 KB
/
station_traitement.sql
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
-- View: qwat_ch_vd_sire.station_traitement
-- DROP VIEW qwat_ch_vd_sire.station_traitement;
CREATE OR REPLACE VIEW qwat_ch_vd_sire.station_traitement AS
SELECT vw_export_installation.id AS "ID_Num",
vw_export_installation.qwat_ext_ch_vd_sire_remarque || vw_export_installation.remark AS "Remarque",
NULL::date AS "Date_de_saisie",
NULL::date AS "Dern_M_a_J",
vw_export_installation.precision_code_sire AS "Precision_Geo",
vw_export_installation.fk_distributor AS "ID_Distributeur",
vw_export_installation.qwat_ext_ch_vd_sire_etat_exploitation AS "Etat_exploitation",
vw_export_installation.year AS "Annee_Construction",
NULL::text AS "Nom_descriptif",
vw_export_installation.folder_identification AS "Numero_dossier",
vw_export_installation.fk_pressurezone AS "ID_Zone_pression",
vw_export_installation.watertype_code_sire AS "Type_eau",
CASE
WHEN vw_export_installation.sanitization_uv IS TRUE THEN 1
ELSE 0
END AS "UV_rayon_Desinfection",
CASE
WHEN vw_export_installation.sanitization_chlorine_liquid IS TRUE THEN 1
ELSE 0
END AS "Chlore_liquide_Desinfection",
CASE
WHEN vw_export_installation.sanitization_chlorine_gazeous IS TRUE THEN 1
ELSE 0
END AS "Chlore_gazeux_Desinfection",
CASE
WHEN vw_export_installation.sanitization_ozone IS TRUE THEN 1
ELSE 0
END AS "Ozone_Desinfection",
CASE
WHEN vw_export_installation.filtration_membrane IS TRUE THEN 1
ELSE 0
END AS "Membrane_Filtration",
CASE
WHEN vw_export_installation.filtration_sandorgravel IS TRUE THEN 1
ELSE 0
END AS "Sable_ou_gravier_Filtration",
CASE
WHEN vw_export_installation.flocculation IS TRUE THEN 1
ELSE 0
END AS "Floculation",
CASE
WHEN vw_export_installation.activatedcharcoal IS TRUE THEN 1
ELSE 0
END AS "Charbon_actif_Filtration",
CASE
WHEN vw_export_installation.settling IS TRUE THEN 1
ELSE 0
END AS "Decantation",
vw_export_installation.treatment_capacity AS "Capacite_traitement",
2 AS "Electricite_pour_fonctionnement",
vw_export_installation.qwat_ext_ch_vd_sire_adesafecter AS "A_Desafecter_PDDE",
st_force2d(vw_export_installation.geometry) AS geometry
FROM qwat_od.vw_export_installation
WHERE vw_export_installation.installation_type = 'treatment'::qwat_od.installation_type AND (vw_export_installation.status_functional IS TRUE OR vw_export_installation.fk_status = 1306);
ALTER TABLE qwat_ch_vd_sire.station_traitement
OWNER TO postgres;