Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathapp.c
149 lines (128 loc) · 5.49 KB
/
app.c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
/***************************************************************************//**
* @file app.c
* @brief Example application
*******************************************************************************
* # License
* <b>Copyright 2024 Silicon Laboratories Inc. www.silabs.com</b>
*******************************************************************************
*
* SPDX-License-Identifier: Zlib
*
* The licensor of this software is Silicon Laboratories Inc.
*
* This software is provided \'as-is\', without any express or implied
* warranty. In no event will the authors be held liable for any damages
* arising from the use of this software.
*
* Permission is granted to anyone to use this software for any purpose,
* including commercial applications, and to alter it and redistribute it
* freely, subject to the following restrictions:
*
* 1. The origin of this software must not be misrepresented; you must not
* claim that you wrote the original software. If you use this software
* in a product, an acknowledgment in the product documentation would be
* appreciated but is not required.
* 2. Altered source versions must be plainly marked as such, and must not be
* misrepresented as being the original software.
* 3. This notice may not be removed or altered from any source distribution.
*
*******************************************************************************
*
* EVALUATION QUALITY
* This code has been minimally tested to ensure that it builds with the
* specified dependency versions and is suitable as a demonstration for
* evaluation purposes only.
* This code will be maintained at the sole discretion of Silicon Labs.
*
******************************************************************************/
#include "mikroe_scd41.h"
#include "sl_sleeptimer.h"
#if (defined(SLI_SI917))
#include "sl_i2c_instances.h"
#include "rsi_debug.h"
#define app_printf(...) DEBUGOUT(__VA_ARGS__)
#define I2C_INSTANCE_USED SL_I2C2
static sl_i2c_instance_t i2c_instance = I2C_INSTANCE_USED;
#else
#include "sl_i2cspm_instances.h"
#include "app_log.h"
#define app_printf(...) app_log(__VA_ARGS__)
#endif
#define READING_INTERVAL_MSEC 5000
static sl_sleeptimer_timer_handle_t app_timer_handle;
static volatile bool trigger_process = false;
static uint16_t ser_num[3];
static mikroe_scd41_measuremen_data_t hvac_data;
static mikroe_scd41_feature_data_t version_data;
static mikroe_i2c_handle_t app_i2c_instance = NULL;
void app_timer_callback(sl_sleeptimer_timer_handle_t *handle, void *data);
void app_init(void)
{
sl_status_t stt;
#if (defined(SLI_SI917))
app_i2c_instance = &i2c_instance;
#else
app_i2c_instance = sl_i2cspm_mikroe;
#endif
app_printf("Hello World - Mikroe HVAC Click example\r\n");
stt = mikroe_scd41_init(app_i2c_instance);
app_printf("Mikroe SCD41 Init = 0x%x\r\n", (uint16_t)stt);
mikroe_scd41_send_cmd(MIKROE_SCD41_PERFORM_FACTORY_RESET);
app_printf("Perform Factory Reset \r\n");
app_printf("-----------------------------------------\r\n");
sl_sleeptimer_delay_millisecond(2000);
stt = mikroe_scd41_get_serial_number(ser_num);
app_printf("mikroe_scd41_get_serial_number = 0x%x\r\n", (uint16_t)stt);
app_printf("SCD41 - Serial Number: %.4d-%.4d-%.4d\r\n",
( uint16_t ) ser_num[0],
( uint16_t ) ser_num[1],
( uint16_t ) ser_num[2]);
app_printf("-----------------------------------------\r\n");
stt = mikroe_scd41_get_feature_set_version(&version_data);
app_printf("mikroe_scd41_get_feature_set_version = 0x%x\r\n", (uint16_t)stt);
app_printf("SCD41 - Features\r\n");
app_printf("Product Type : %d \r\n",
( uint16_t ) version_data.product_type);
app_printf("Platform Type : %d \r\n",
( uint16_t ) version_data.platform_type);
app_printf("Product Version : %d.%d \r\n",
( uint16_t ) version_data.product_major_version,
( uint16_t ) version_data.product_minor_version);
app_printf("-----------------------------------------\r\n");
// Trigger measure single shot */
mikroe_scd41_send_cmd(MIKROE_SCD41_MEASURE_SINGLE_SHOT);
app_printf("sl_sleeptimer_start_periodic = 0x%lx\r\n",
sl_sleeptimer_start_periodic_timer_ms(&app_timer_handle,
READING_INTERVAL_MSEC,
app_timer_callback,
NULL,
0,
0));
}
/***************************************************************************//**
* App ticking function.
******************************************************************************/
void app_process_action(void)
{
if (trigger_process) {
trigger_process = false;
sl_status_t stt = mikroe_scd41_read_measurement(&hvac_data);
if (SL_STATUS_OK == stt) {
app_printf("CO2 Concent = %dppm\r\n", hvac_data.co2_concent);
app_printf("Temperature = %.2f%cC \r\n", hvac_data.temperature, 176);
app_printf("R.Humidity = %.2f %% \r\n", hvac_data.r_humidity);
app_printf("-----------------------------------------\r\n");
// Continue trigger measure single shot
mikroe_scd41_send_cmd(MIKROE_SCD41_MEASURE_SINGLE_SHOT);
} else {
app_printf("Error, code = 0x%lx\r\n", stt);
while (1) {}
}
}
}
void app_timer_callback(sl_sleeptimer_timer_handle_t *handle, void *data)
{
(void) data;
(void) handle;
trigger_process = true;
}