diff --git a/config/goodway/tc13010.xml b/config/goodway/tc13010.xml
new file mode 100644
index 0000000000..57dd2e3299
--- /dev/null
+++ b/config/goodway/tc13010.xml
@@ -0,0 +1,79 @@
+
+
+ In-wall switch
+ This In-wall Power Monitor Switch is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini-sized design makes it easy to place the In-wall Power Monitor Switch into the wall box and fit in the house decoration.
+ https://products.z-wavealliance.org/products/2948
+
+
+ Connect the module to the power supply. Enable inclusion mode on your Z-Wave controller. Press and release the Include/Exclude button 3 times within 2 seconds.
+ Connect the module to the power supply. Make sure the module is within direct range of your Z-Wave controller or use a hand-held Z-Wave remote to perform exclusion. Press and release the Include/Exclude button 3 times within 2 seconds. NOTE: The module will be excluded from your network, but any custom configuration parameters will not be erased.
+ Connect the module to the power supply. Press and hold the Include/Excude button for at least 10 seconds. NOTE: By resetting the module, all custom parameters previously set on the module will return to their default values and the owner ID will be deleted. Use this reset procedure only when the main controller is missing or otherwise inoperable.
+ https://products.z-wavealliance.org/products/2948/features
+ CEPT (Europe) (EU)
+ TD13010
+
+ Initial release
+
+
+
+
+
+ Time in seconds after that the Load 1 will turn off. 0 - no turn off. Default - 0.
+
+
+ Time in seconds after that the Load 2 will turn off. 0 - no turn off. Default - 0.
+
+
+
+
+
+
+
+
+
+
+
+
+
+ Power change magnitude that triggers reporting to the controller. 0% - no reporting. Default is 10%.
+
+
+ Accepted values range: 60-32767. 0 - no reporting. Default - 300 sec.
+
+
+ Accepted values range: 60-32767. 0 - no reporting.
+
+
+ Time in seconds after that the Load 1 will turn on. 0 - no turn off. Default - 0.
+
+
+ Time in seconds after that the Load 2 will turn on. 0 - no turn off. Default - 0.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ true
+
+
+
diff --git a/config/manufacturer_specific.xml b/config/manufacturer_specific.xml
index e8d94ae232..7f729e8cdc 100644
--- a/config/manufacturer_specific.xml
+++ b/config/manufacturer_specific.xml
@@ -878,6 +878,7 @@
+