From 9a230f5d463c2bfae208f9e6f9150e014f40a1f6 Mon Sep 17 00:00:00 2001 From: Scott Horowitz Date: Fri, 23 Feb 2024 11:43:20 -0700 Subject: [PATCH] Update tests. --- rulesets/tests/test_hvac.rb | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/rulesets/tests/test_hvac.rb b/rulesets/tests/test_hvac.rb index 9cbde006c..e5f33ef5a 100644 --- a/rulesets/tests/test_hvac.rb +++ b/rulesets/tests/test_hvac.rb @@ -669,7 +669,7 @@ def test_shared_boiler_baseboard _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 208 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric @@ -690,7 +690,7 @@ def test_shared_boiler_fan_coil _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600, fan_coil_watts: 150 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 520 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric @@ -711,7 +711,7 @@ def test_shared_boiler_fan_coil_ducted _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600, fan_coil_watts: 150 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 520 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric @@ -732,7 +732,7 @@ def test_shared_boiler_water_loop_heat_pump _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 208 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric