diff --git a/rulesets/tests/test_hvac.rb b/rulesets/tests/test_hvac.rb index 9cbde006c..e5f33ef5a 100644 --- a/rulesets/tests/test_hvac.rb +++ b/rulesets/tests/test_hvac.rb @@ -669,7 +669,7 @@ def test_shared_boiler_baseboard _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 208 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric @@ -690,7 +690,7 @@ def test_shared_boiler_fan_coil _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600, fan_coil_watts: 150 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 520 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric @@ -711,7 +711,7 @@ def test_shared_boiler_fan_coil_ducted _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600, fan_coil_watts: 150 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 520 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric @@ -732,7 +732,7 @@ def test_shared_boiler_water_loop_heat_pump _all_calc_types.each do |calc_type| _hpxml, hpxml_bldg = _test_ruleset(hpxml_name, calc_type) if [Constants.CalcTypeERIRatedHome].include? calc_type - _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, shared_loop_watts: 600 }]) + _check_heating_system(hpxml_bldg, [{ systype: HPXML::HVACTypeBoiler, fuel: HPXML::FuelTypeNaturalGas, eff: 0.92, frac_load: 1.0, num_units_served: 6, eae: 208 }]) else hvac_iq_values = _get_default_hvac_iq_values(eri_version, 0.5) if [Constants.CalcTypeCO2eReferenceHome].include? calc_type # All-electric