Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Update library for specification [v1-06] 2019-Feb-07 #2

Open
LucAce opened this issue Jan 30, 2020 · 0 comments
Open

Update library for specification [v1-06] 2019-Feb-07 #2

LucAce opened this issue Jan 30, 2020 · 0 comments
Assignees

Comments

@LucAce
Copy link
Owner

LucAce commented Jan 30, 2020

The application which runs on the sensor has been updated by the manufacturer. The library needs to be updated to support the changes.

Most notable are:

eCO2
The equivalent CO2 (eCO2) output range for CCS811 is from 400ppm up to 29206ppm.

eTVOC
The equivalent Total Volatile Organic Compound (eTVOC) output range for CCS811 is from 0ppb up to 32768ppb.

Updated “FW_App_Version (Firmware Application Version) Register (0x24)”

Latest datasheet specification:
https://ams.com/ccs811

@LucAce LucAce self-assigned this Jan 30, 2020