Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathcheck_ad.vbs
216 lines (194 loc) · 6.8 KB
/
check_ad.vbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
'Script to check the status of a DOMAIN controller and report to Nagios
'requires DCDIAG.EXE
'Author: Felipe Ferreira
'Version: 3.2
'Updated by: Guillaume ONA : Add detection of code page and French support
'
'Mauled over by John Jore, j-o-h-n-a-t-j-o-r-e-d-o-t-n-o 16/11/2010 to work on W2K8, x32
'as well as remove some, eh... un-needed lines of code, general optimization as well as adding command parameter support
'This is where i found the original script, http://felipeferreira.net/?p=315&cpage=1#comments
'Tested by JJ on W2K8 SP2, x86
' W2K3 R2 SP2, x64
'Version 3.0-JJ-V0.2
'Todo: Proper error handling
' Add support for the two tests which require additional input (dcpromo is one such test)
'Force all variables to be declared before usage
option explicit
'Array for name and status (Ugly, but redim only works on last dimension, and can't set initial size if redim
dim name(), status()
redim preserve name(0)
redim preserve status(0)
'Debug switch
dim verbose : verbose = 0
'Return variables for NAGIOS
const intOK = 0
const intWarning = 1 'Not used. What dcdiag test would be warning instead of critical?
const intCritical = 2
const intUnknown = 3
'Lang dependend
dim strOK : strOK = "passed"
dim strNotOK : strNotOk = "failed"
'Call dcdiag and grab relevant output
exec(cmd)
'Generate NAGIOS compatible output from dcdiag
printout()
'call dcdiag and parse the output
sub exec(strCmd)
'Declare variables
dim objShell : Set objShell = WScript.CreateObject("WScript.Shell")
dim oExec1 : Set oExec1=objShell.Exec("cmd /c chcp")
dim conv : Set conv=CreateObject("OlePrn.OleCvt")
dim objExecObject, lineout, tmpline, mess, ssaccent
dim page_code
lineout = ""
'Command line options we're using
pt strCmd
mess=oExec1.StdOut.ReadAll
page_code = Split(mess,":",-1,1)
Set objExecObject = objShell.Exec(strCmd)
'Loop until end of output from dcdiag
do While not objExecObject.StdOut.AtEndOfStream
ssaccent = conv.ToUnicode(objExecObject.StdOut.ReadLine(),trim(page_code(1)))
tmpline = lcase(ssaccent)
call parselang(tmpline)
lineout = lineout + tmpline
if (instr(tmpline, ".....")) then
'testresults start with a couple of dots, so lets reset the lineout buffer
lineout= tmpline
end if
if instr(lineout, lcase(strOK)) then
'we have a strOK String which means we have reached the end of a result output (maybe on newline)
call parse(lineout)
lineout = ""
end if
loop
call parse(lineout)
end sub
sub parselang(txtp)
txtp = Replace(txtp,chr(10),"") ' Newline
txtp = Replace(txtp,chr(13),"") ' CR
txtp = Replace(txtp,chr(9),"") ' Tab
do while instr(txtp, " ")
txtp = Replace(txtp," "," ") ' Some tidy up
loop
if (instr(lcase(txtp), lcase("Domain Controller Diagnosis"))) then ' English
strOK = "passed"
strNotOk = "failed"
end if
if (instr(lcase(txtp), lcase("Verzeichnisserverdiagnose"))) then ' German
strOK = "bestanden"
strNotOk = "nicht bestanden"
end if
if (instr(lcase(txtp), lcase("Diagnostic du serveur d'annuaire"))) then ' French
strOK = "réussi"
strNotOk = "échoué"
end if
end sub
sub parse(txtp)
'Parse output of dcdiag command and change state of checks
dim loop1
txtp = Replace(txtp,chr(10),"") ' Newline
txtp = Replace(txtp,chr(13),"") ' CR
txtp = Replace(txtp,chr(9),"") ' Tab
do while instr(txtp, " ")
txtp = Replace(txtp," "," ") ' Some tidy up
loop
' We have to test twice because some localized (e.g. German) outputs simply use not as a prefix
if instr(lcase(txtp), lcase(strOK)) then
'What are we testing for now?
pt txtp
'What services are ok? 'By using instr we don't need to strip down text, remove vbCr, VbLf, or get the hostname
for loop1 = 0 to Ubound(name)-1
if (instr(lcase(txtp), lcase(name(loop1)))) then status(loop1)="OK"
next
' if we found the strNotOK string then reset to CRITICAL
if instr(lcase(txtp), lcase(strNotOK)) then
'What are we testing for now?
pt txtp
for loop1 = 0 to Ubound(name)-1
if (instr(lcase(txtp), lcase(name(loop1)))) then status(loop1)="CRITICAL"
next
end if
end if
end sub
'outputs result for NAGIOS
sub printout()
dim loop1, msg : msg = ""
for loop1 = 0 to ubound(name)-1
msg = msg & name(loop1) & ": " & status(loop1) & ". "
next
'What state are we in? Show and then quit with NAGIOS compatible exit code
if instr(msg,"CRITICAL") then
wscript.echo "CRITICAL - " & msg
wscript.quit(intCritical)
else
wscript.echo "OK - " & msg
wscript.quit(intOK)
end if
end sub
'Print messages to screen for debug purposes
sub pt(msgTxt)
if verbose then
wscript.echo msgTXT
end if
end sub
'What tests do we run?
function cmd()
dim loop1, test, tests
cmd = "dcdiag " 'Start with this
'If no command line parameters, then go with these defaults
if Wscript.Arguments.Count = 0 Then
redim preserve name(6)
redim preserve status(6)
'Test name
name(0) = "services"
name(1) = "replications"
name(2) = "advertising"
name(3) = "fsmocheck"
name(4) = "ridmanager"
name(5) = "machineaccount"
'Status
for loop1 = 0 to (ubound(name)-1)
status(loop1) = "CRITICAL"
cmd = cmd & "/test:" & name(loop1) & " "
next
else
for loop1 = 0 to wscript.arguments.count - 1
if lcase(wscript.Arguments(loop1)) = "/help" then
wscript.echo "Usage : (with or without //nologo)" & VbCrLf & _
" This script require dcdiag.exe " & VbCrLf & _
" cscript.exe check_ad.vbs //nologo" & VbCrLf & _
" cscript.exe check_ad.vbs //nologo /test:services" & VbCrLf & _
" cscript.exe check_ad.vbs /test:services,fsmocheck,machineaccount" & VbCrLf & VbCrLf & _
" ..::: For valid check, execute the script without arguments :::.."
wscript.quit(intUnknown)
end if
if (instr(lcase(wscript.Arguments(loop1)), lcase("/test"))) then
'If parameter is wrong, give some hints
if len(wscript.arguments(loop1)) < 6 then
wscript.echo "UNKNOWN ? Parameter wrong specify test like /test:advertising,dfsevent"
wscript.quit(intUnknown)
end if
'Strip down the test to individual items
tests = right(wscript.arguments(loop1), len(wscript.arguments(loop1))-6)
pt "Tests: '" & tests & "'"
tests = split(tests,",")
for each test in tests
cmd = cmd & " /test:" & test
'Expand the array to make room for one more test
redim preserve name(ubound(name)+1)
redim preserve status(ubound(status)+1)
'Store name of test and status
name(Ubound(name)-1) = test
status(Ubound(status)-1) = "CRITICAL" 'Default status. Change to OK if test is ok
'pt "Contents: " & name(Ubound(name)-1) & " " & status(Ubound(status)-1)
next
else
wscript.echo "UNKNOWN - Invalid arguments :" & wscript.Arguments(loop1) & " , use /help for list of valid arguments"
wscript.quit(intUnknown)
end if
next
end if
'We end up with this to test:
pt "Command to run: " & cmd
end function